Mercurial > prosody-modules
view mod_s2s_keepalive/mod_s2s_keepalive.lua @ 3568:6b3181fe5617
mod_auth_token: Timezone fix for TOTP checking
luatz.time() returns milliseconds since epoch which is in UTC time, so we don't
need to convert to UTC with gmtime.
By calling gmtime, TOTP validation was failing when this module wasn't running
on machine set to UTC time.
author | JC Brand <jc@opkode.com> |
---|---|
date | Thu, 02 May 2019 11:07:27 +0200 |
parents | 2db2c03dfb95 |
children | 427879b46061 |
line wrap: on
line source
local st = require "util.stanza"; local keepalive_servers = module:get_option_set("keepalive_servers"); local keepalive_interval = module:get_option_number("keepalive_interval", 60); local host = module.host; local function send_pings() for remote_domain, session in pairs(hosts[host].s2sout) do if session.type == "s2sout" -- as opposed to _unauthed and (not(keepalive_servers) or keepalive_servers:contains(remote_domain)) then session.sends2s(st.iq({ to = remote_domain, type = "get", from = host, id = "keepalive" }) :tag("ping", { xmlns = "urn:xmpp:ping" }) ); -- Note: We don't actually check if this comes back. end end for session in pairs(prosody.incoming_s2s) do if session.type == "s2sin" -- as opposed to _unauthed and (not(keepalive_servers) or keepalive_servers:contains(session.from_host)) then session.sends2s " "; -- If the connection is dead, this should make it time out. end end return keepalive_interval; end if module.add_timer then -- 0.9 module:add_timer(keepalive_interval, send_pings); else -- 0.8 local timer = require "util.timer"; local unloaded; timer.add_task(keepalive_interval, function() if not unloaded then return send_pings() end end); function module.unload() unloaded = true end end