view mod_measure_message_length/mod_measure_message_length.lua @ 5505:efe9e741f222

mod_http_oauth2: Correct loopback URL example The s in the scheme should not be there, only unencrypted http to loopback interface is allowed.
author Kim Alvefur <zash@zash.se>
date Thu, 01 Jun 2023 19:37:17 +0200
parents 6e70d354b7d8
children
line wrap: on
line source

local bytes = module:measure("bytes", "sizes");
local lines = module:measure("lines", "distribution");
local words = module:measure("words", "distribution");

local function measure_length(event)
	local body = event.stanza:get_child_text("body");
	if body then
		bytes(#body);
		lines(select(2, body:gsub("[^\n]+","")));
		words(select(2, body:gsub("%S+","")));
	end
end

module:hook("message/full", measure_length);
module:hook("message/bare", measure_length);
module:hook("message/host", measure_length);

module:hook("pre-message/full", measure_length);
module:hook("pre-message/bare", measure_length);
module:hook("pre-message/host", measure_length);